Media Summary: Objective: Take out the viscoelastic inside. - Press down on the Objective: - Make the spheres as small as possible, get them into a group in the center, then consume all four small spheres at ... Objective: Practice hydrodissection and hydro-delineation. - Hydrodissection is well done if you can spin the cortex afterwards (as ...

Eyesi Cat B Iol Insertion - Detailed Analysis & Overview

Objective: Take out the viscoelastic inside. - Press down on the Objective: - Make the spheres as small as possible, get them into a group in the center, then consume all four small spheres at ... Objective: Practice hydrodissection and hydro-delineation. - Hydrodissection is well done if you can spin the cortex afterwards (as ... Objective: Perform capsulorhexis with the flap at the 0' CW, with low tension. - Inject plenty of viscoelastic - Start at the very edge ... Objective: Perform capsulorhexis with the flap at 0' CCW, with low tension. - Inject plenty of viscoelastic - Start at the very edge of ... Objective: Holding the nucleus in place and chopping with precision. - Keep the O/R setting - Preset to 'Quad removal 1'.

Objective: Try to bring the spheres at the ends of each object together. - Make sure the tips of the instrument are buried in each ... Objective: Remove the remaining cortex - much easier in this level to cause a capsular rupture/tear. - be very slow and methodical ... Objective: Perform capsulorhexis with the flap at the 90' CCW, with low tension. - Inject plenty of viscoelastic - Start at the very ... All beginning cataract surgeons must know how to load the Objective: Split the lens O/R Settings: Continuous irrigation, Quad removal 1, 275 vacuum (TIP: turn it up 30-40 up from the default ... Objective: Perform capsulorhexis with the flap at the 90' CW, with low tension. - Inject plenty of viscoelastic - Start at the very edge ...

Objective: Remove the viscoelastic around the toric Objective: Split the lens O/R Settings: Continuous irrigation, Quad removal 1, 275 vacuum. 1. Bury the phaco tip to hold the lens 2. Objective: Capsulorhexis on the white cataract with low capsular tension 1. Air bubble, trypan blue, BSS 2. Pierce the center, and ...

Photo Gallery

EyeSi CAT B IOL Insertion, Level 1 (spheric IOL inserted, remove viscoelastic)
EyeSi CAT B IOL Insertion, Level 3 (insert spheric IOL)
EyeSi CAT B IOL Insertion, Level 7 (correct misplaced spheric IOL)
EyeSi CAT B Phaco Training, Level 3
EyeSi CAT B Hydro Maneuvers, Level 1 (very soft lens, light attachment)
EyeSi CAT B Initial Flap CW 0 Degrees, Low Tension
EyeSi CAT B Initial Flap CCW 0 Degrees, Low Tension
EyeSi CAT B Phaco Chopping Training, Level 1 (half nucleus, horizontal chopper)
EyeSi CAT B Cracking & Chopping Training, Level 5
EyeSi CAT C Irrigation and Aspiration, Level 4
EyeSi CAT B Initial Flap CCW 90 Degrees, Low Tension
How to load a single-piece Acrylic IOL into the injector for cataract surgery
Sponsored
Sponsored
View Detailed Profile
Sponsored
Sponsored