Media Summary: Objective: Holding the nucleus in place and chopping with precision. - Keep the O/R setting - Preset to 'Quad removal 1'. Objective: - Make the spheres as small as possible, get them into a group in the center, then consume all four small spheres at ... Objective: Take out the viscoelastic inside. - Press down on the intraocular lens to collect the viscoelastic - Dr. Michael Mak and ...
Eyesi Cat B Phaco Training - Detailed Analysis & Overview
Objective: Holding the nucleus in place and chopping with precision. - Keep the O/R setting - Preset to 'Quad removal 1'. Objective: - Make the spheres as small as possible, get them into a group in the center, then consume all four small spheres at ... Objective: Take out the viscoelastic inside. - Press down on the intraocular lens to collect the viscoelastic - Dr. Michael Mak and ... Objective: Split the lens O/R Settings: Continuous irrigation, Quad removal 1, 275 vacuum. 1. Bury the Objective: Split the lens O/R Settings: Continuous irrigation, Quad removal 1, 275 vacuum (TIP: turn it up 30-40 up from the default ... Objective: Perform capsulorhexis with the flap at the 0' CW, with medium tension. - Inject plenty of viscoelastic - Start at the very ...
Objective: Insert the IOL - Do not put too much viscoelastic. - Remove the inserter as the IOL is inserted. - If IOL slips out, IA tip to ... Objective: Move the sphere around the circular path traced by the blue line, in a counter-clockwise fashion. - Be as stable and still ... Objective: Try to bring the spheres at the ends of each object together. - Make sure the tips of the instrument are buried in each ... Objective: Perform capsulorhexis with the flap at 0' CCW, with low tension. - Inject plenty of viscoelastic - Start at the very edge of ... Objective: Drag the sphere along the highlighted sphere - Make sure the tip of your instrument is buried deep inside the sphere at ... Objective: Perform capsulorhexis with the flap at the 0' CW, with low tension. - Inject plenty of viscoelastic - Start at the very edge ...
Objective: Remove the remaining cortex - much easier in this level to cause a capsular rupture/tear. - be very slow and methodical ... Objective: Use both instrument to touch the ends of an object simultaneously Make sure to: - get the tip of both instrument to the ... Objective: Practice hydrodissection and hydro-delineation. - Hydrodissection is well done if you can spin the cortex afterwards (as ... Objective: Split the lens (go horizontal with the chopper instead of vertical) O/R Settings: Continuous irrigation, Quad removal 1, ... Objective: Insert the IOL - Push IOL back into place with any instrument - Use the irrigation/aspiration probe to aspirate rest of the ...